Main component units and performance: | |||||
1 | Twinturbineatomizerheadmodule | 1 group | |||
Drive mode: pneumatic double turbo | |||||
Diameter X length (mm): 220X850 | |||||
Atomizing disk (mm): Φ180mm | |||||
Rotation speed (disc diameter 180mm): 25000rpm | |||||
Air consumption: 0.8Nm3/min | |||||
2 | Electrostatic high voltage generator module (0-120KV adjustable) | 1 group | |||
High voltage output: automatic boost, constant voltage output. | |||||
Safety measures: automatic detection of current changes, reflex protection circuit characteristics, no spark generation | |||||
Input voltage: 220VAC, 50Hz | |||||
Output voltage: Max. 100KV (max. 120KV), negative polarity, adjustable; stable performance, long service life. | |||||
Output current: Max.300mA, adjustable. | |||||
With automatic safety protection function: the transient voltage and current will automatically jump off, and manual re-setting is required when starting; with automatic protection safety measures | |||||
Applicable environment: 0-40 degrees Celsius. | |||||
3 | PrecisionGearPumpCoatingSupply Module | 1 group | |||
Applicable paints: Plain paint, metallic paint, etc. are suitable. | |||||
Flow rate monitoring: Current flow rate is displayed on the man-machine interface. | |||||
Gear pump specification: 3cc/rpm; | |||||
Drive device: Three-phase AC motor. | |||||
Flow control method: Inverter control, TECO brand. | |||||
Paint flow adjustment: set on the human-machine interface, linear stepless adjustment. | |||||
4 | Verticalreciprocatingmachinemodule | 1 group | |||
Track structure:Straight track | |||||
Maximum travel: mm; (to be determined) | |||||
Running speed: 45m/min. | |||||
Drive motor: three-phase AC motor. | |||||
multi-segment speed: 4-8 segment speed variation | |||||
control mode: inverter control. | |||||
rated voltage: 220V, 50Hz. | |||||
effective load: about 200Kg. | |||||
5 | Central control box | 1 group | |||
Operationmode: 7-inch monochrome human-machine interface | |||||
Storage capacity: 40 sets of spraying programs | |||||
Control mode: PLC | |||||
Safetyinterlock:interlockwithoutputlineandthrough-side system | |||||
Operating voltage: 220V AC, 50Hz | |||||
Alarm mode: buzzer sound alarm | |||||
Air heater: 1 set | |||||
Function Description.
1. All spraying conditions are set on the human-machine interface, except for the spraying plate speed which is not set manually, and the time type is managed digitally. 2. 8-step speed control in the lift's effective stroke 3. Static voltage control and display 4. Gear pump flow control and display 5. Cleaning control 6. 4-8 stage change control of paint volume in effective stroke (save 10-20% compared with traditional control) |
|||||
6 | Installation Materials | 1 group | |||
Special leak-proof double-layer oil pipe | |||||
Air lines. | |||||
Other installation materials. | |||||
7 | Installationandcommissioning,education, mass production introduction, warranty | 1 group | |||
Pre-assembly and testing of equipment before leaving the factory. | |||||
On-site equipment assembly and testing. | |||||
Program instruction and debugging of customer workpieces. | |||||
Trainingofcustomertechniciansinoperation,maintenance and repair. | |||||
Introduction of a product into mass production. | |||||
One-yearwarrantyfornon-consumablepartsofthe entire equipment. | |||||
Life-long "escort" quality after-sales service. |